AIC XD1100-1102 Bedienungsanleitung Seite 19

  • Herunterladen
  • Zu meinen Handbüchern hinzufügen
  • Drucken
  • Seite
    / 72
  • Inhaltsverzeichnis
  • LESEZEICHEN
  • Bewertet. / 5. Basierend auf Kundenbewertungen
Seitenansicht 18
1U10 RBOD User’s Manual
Copyright© 2010 Advanced Industrial Computer, Inc. Page 19 of 72
All Rights Reserved. Rev.1.05
; All external cables are properly connected and secured.
; Power cables are installed.
; Power from a suitable power source
; The system should have been in place long enough to adjust to ambient temperature.
3.1.1. Powering On the System
After the 1U10 is mounted in the rack, drive trays inserted, and external connections completed,
the system may be powered on using the following steps.
1) If you have not already done so, using the power cords supplied connect the PSU
modules to the power source. If the power is on, LED indicators on the Expanders will
flash indicating power is present and the System is in standby mode.
2) Power on any network switches in the configuration.
3) Turn on the power switch on the rear panel to power up the system. The fans should
come on immediately afterwards and the drives will begin to spin up and initialize.
4) Allow a few minutes for drive initialization to complete prior to powering on Host
System or Storage Appliances or Controllers.
5) After completing system configuration proceed to power on external hosts or Storage
Appliances and Controllers. It is recommended hosts be powered on last unless the
system is being installed into a live/hot environment.
3.1.2. Power On Status
Once the system has been powered on, the Display can be checked to verify proper operation.
System monitoring and status information is collected via the internal I
2
C bus and is made
available via external controllers and management tools via SES.
Drive LED status will be steady Blue indicating power on idle state or intermittent Blue
indicating Drive activity.
Expander LEDs will be flashing intermittent to indicate activity
3.1.3. Power Off the System
1) Flush and unmount all the volumes, and/or power off all the servers accessing volumes
on the system to be powered down, prior to powering down the unit.
2) Press the On/Off button on the rear panel.
3) Allow a few minutes for the drives to spin down.
Warning: The system has 2 hot swap auto-ranging power supplies. These should be
connected to suitable grounded 100-120V or 210-240V AC power sources. It is recommended
separate power sources or rails be used for maximum redundancy and reliability.
Warning: The system requires adequate open space front and rear to allow for proper cooling.
Seitenansicht 18